Language:
Customer Testimonials
Quick response
2016-05-04 22:46:23


From: Bennett, Dan [mailto:]
Sent: Thursday, April 21, 2016 4:20 PM
To: paul vanevery <pvanevery@soph-inc.com>
Subject: RE: Magnet status 1000 ton Van Dorn


Paul,

 

Thanks for the report and your quick response yesterday.

 

From: paul vanevery [mailto:pvanevery@soph-inc.com]
Sent: Thursday, April 21, 2016 1:42 PM
To: Bennett, Dan <>
Cc: 'edely' <edely@soph-inc.com>; 'Shawn Byers' <shawnbyers@soph-inc.com>
Subject: Magnet status 1000 ton Van Dorn


Hi Dan,


To go over my notes I am writing this down.

When I arrived at the press I found that our magnet controller was in an alarm state. The e-stop circuit dry contact across wire 70-71 was open in our controller. This opens in any alarm condition.

The dry contact across 70A and 71A for machine enable was also open.

The MSD alarm light was ...